TY - GEN
T1 - A non-invasive algorithm of the continuous intra-abdominal pressure measurement using parametric curve fitting method
AU - Kim, K. S.
AU - Song, C. G.
AU - Seo, J. H.
PY - 2009
Y1 - 2009
N2 - The rectal pressure is considered to be the 'gold standard' for the assessment of the intra-abdominal pressure (IAP). However, conventional rectal catheters can cause erroneous results, and it is not comfortable for the patients. To reduce these problems, we contrived a non-invasive measurement of the IAP using the parametric curve fitting method, such as using a linear, quadratic, cubic, quartic, exponential and sine equation modeling, between the rectal pressure and the root mean square (RMS) values of surface electromyographic (sEMG) signals, recorded simultaneously from the abdomen. The study group consisted of 12 patients (7 males and 5 females) with neurogenic bladders due to spinal cord injury. The average age and body mass index of the subjects were 53.2 (S.D. ±11.9) years and 24.4 (S.D. ±2.7), respectively. By our devised algorithm, the correlation coefficient and root mean square error (RMSE) between the measured and estimated IAP by the quartic polynomial modeling, were 0.86±0.05 and 4.70±1.56, respectively. This method suggested that the sEMG should be used reliably for the indirect measurement of the IAP in ambulatory urodynamics monitoring studies.
AB - The rectal pressure is considered to be the 'gold standard' for the assessment of the intra-abdominal pressure (IAP). However, conventional rectal catheters can cause erroneous results, and it is not comfortable for the patients. To reduce these problems, we contrived a non-invasive measurement of the IAP using the parametric curve fitting method, such as using a linear, quadratic, cubic, quartic, exponential and sine equation modeling, between the rectal pressure and the root mean square (RMS) values of surface electromyographic (sEMG) signals, recorded simultaneously from the abdomen. The study group consisted of 12 patients (7 males and 5 females) with neurogenic bladders due to spinal cord injury. The average age and body mass index of the subjects were 53.2 (S.D. ±11.9) years and 24.4 (S.D. ±2.7), respectively. By our devised algorithm, the correlation coefficient and root mean square error (RMSE) between the measured and estimated IAP by the quartic polynomial modeling, were 0.86±0.05 and 4.70±1.56, respectively. This method suggested that the sEMG should be used reliably for the indirect measurement of the IAP in ambulatory urodynamics monitoring studies.
UR - https://www.scopus.com/pages/publications/67650666733
U2 - 10.1109/ICCME.2009.4906599
DO - 10.1109/ICCME.2009.4906599
M3 - Conference paper
AN - SCOPUS:67650666733
SN - 9781424433162
T3 - 2009 ICME International Conference on Complex Medical Engineering, CME 2009
BT - 2009 ICME International Conference on Complex Medical Engineering, CME 2009
T2 - 2009 ICME International Conference on Complex Medical Engineering, CME 2009
Y2 - 9 April 2009 through 11 April 2009
ER -