An unusual complication of pyloric ring obstruction caused by flange of lumen apposing metal stent in endoscopic ultrasound-guided gallbladder drainage: A case report

Research output: Contribution to journalJournal articlepeer-review

Abstract

Introduction:Endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) is an alternative treatment option for patients with acute cholecystitis, especially for those who are unsuitable for cholecystectomy. Recently used luminal apposing metal stents (LAMS) in EUS-GBD has several advantages over standard metal stents. However, there is no current guideline on where to locate the LAMS when transgastric approach is required. This study reports a case of gastric outlet obstruction (GOO) by placing LAMS too close to the pyloric ring.Patient concerns:A 79-year-old female patient was referred to our department for evaluation of a large hepatic mass on abdominal ultrasound. Abdominal pain on right upper quadrant and spiking fever up to 38 °C appeared after liver biopsy. Abdominal ultrasound showed thickened GB wall and positive sonographic Murphy sign.Diagnoses:Intrahepatic cholangiocarcinoma with multiple lung and intrahepatic metastasis, acute cholecystitis, and pyloric ring obstruction caused by flange of LAMS in EUS-GBD.Interventions:EUS-GBD via transgastric approach was performed with LAMS. After complete deployment of stent, esophagogastroduodenoscopy showed complete GOO by flange of LAMS. A gastroduodenal metal stent was inserted to relieve the GOO.Outcomes:The patient recovered well. She did not complain about obstruction induced symptom such as vomiting or abdominal fullness after gastroduodenal stent insertion.Conclusion:To the best of our knowledge, this is the first case report of EUS-GBD induced GOO. If physicians use LAMS as a transgastric approach in EUS-GBD, the puncture site should be carefully selected considering the size of the flange.

Original languageEnglish
Pages (from-to)E21017
JournalMedicine (United States)
Volume99
Issue number27
DOIs
StatePublished - 2020.07.2

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • acute cholecystitis
  • complication
  • endoscopic ultrasound-guided gallbladder drainage
  • gastric outlet obstruction
  • lumen-apposing metal stent