Skip to main navigation Skip to search Skip to main content

Comparison of transient severe motion in gadoxetate disodium and gadopentetate dimeglumine-enhanced MRI: effect of modified breath-holding method

Research output: Contribution to journalJournal articlepeer-review

Abstract

Objectives: To compare the occurrence of transient severe motion (TSM) between gadoxetate disodium- and gadopentetate dimeglumine-enhanced MRI and between gadoxetate disodium-enhanced MRI scans obtained with and without the application of a modified breath-holding technique. Methods: We reviewed 80 patients who underwent two magnetic resonance examinations (gadoxetate disodium-enhanced MRI and gadopentetate dimeglumine-enhanced MRI) with the application of a modified breath-holding technique (dual group). This group was compared with 100 patients who underwent gadoxetate disodium-enhanced MRI without the application of the modified breath-holding technique (single group). Patient risk factors and motion scores (1 [none] to 5 [non-diagnostic]) for each dynamic-phase imaging were analysed. Results: In the dual group, mean motion scores did not differ significantly between gadoxetate disodium- and gadopentetate dimeglumine-enhanced MRI (p=0.096–0.807) in any phase. However, in all phases except the late dynamic phase, mean motion scores of the dual group were significantly lower than those in the single group. TSM incidence did not differ significantly between gadoxetate disodium- and gadopentetate dimeglumine-enhanced MRI in the dual group (3.8% vs. 1.3%, p=0.620). Conclusion: With proper application of the modified breath-holding technique, TSM occurrence with gadoxetate disodium-enhanced MRI was comparable to that associated with gadopentetate dimeglumine-enhanced MRI. Key Points: • The modified breath-holding method significantly reduced the incidence of TSM. • Gadoxetate disodium and gadopentetate dimeglumine showed comparable motion scores. • TSM incidence was comparable between gadoxetate disodium- and gadopentetate dimeglumine-enhanced MRI.

Original languageEnglish
Pages (from-to)1132-1139
Number of pages8
JournalEuropean Radiology
Volume28
Issue number3
DOIs
StatePublished - 2018.03.1

Keywords

  • Arterial phase
  • Gadopentetate dimeglumine
  • Gadoxetate disodium
  • Magnetic resonance imaging
  • Motion artefact

Quacquarelli Symonds(QS) Subject Topics

  • Medicine

Fingerprint

Dive into the research topics of 'Comparison of transient severe motion in gadoxetate disodium and gadopentetate dimeglumine-enhanced MRI: effect of modified breath-holding method'. Together they form a unique fingerprint.

Cite this