Abstract

This paper presents a compensation method of dead time effects in a grid-tied single-phase inverter. In general, output current of grid-tied inverter contains odd-numbered harmonics because of dead time and nonlinear characteristics of the switching devices. Thus, in this paper, effects of dead time in output voltage and current are analyzed in detail. Also, a new compensation algorithm using Second-order Generalized Integrator (SOGI) is proposed to reduce the dead time effect. Simulation and experimental results validate the effectiveness of proposed algorithm.

Original languageEnglish
Title of host publication2017 IEEE Applied Power Electronics Conference and Exposition, APEC 2017
PublisherInstitute of Electrical and Electronics Engineers Inc.
Pages2633-2637
Number of pages5
ISBN (Electronic)9781509053667
DOIs
StatePublished - 2017.05.17
Event32nd Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2017 - Tampa, United States
Duration: 2017.03.262017.03.30

Publication series

NameConference Proceedings - IEEE Applied Power Electronics Conference and Exposition - APEC

Conference

Conference32nd Annual IEEE Applied Power Electronics Conference and Exposition, APEC 2017
Country/TerritoryUnited States
CityTampa
Period17.03.2617.03.30

Keywords

  • Current ripple compensation
  • Dead time
  • Single-phase grid-connected inverter
  • SOGI

Fingerprint

Dive into the research topics of 'Compensation of dead time effects in grid-tied single-phase inverter using SOGI'. Together they form a unique fingerprint.

Cite this