Skip to main navigation Skip to search Skip to main content

Correction of pseudoreticulocytosis in leukocytosis samples using the sysmex XE-2100 analyzer depends on the type and number of white blood cells

  • Ahhyun Kim
  • , Joonhong Park
  • , Myungshin Kim
  • , Jihyang Lim
  • , Eun Jee Oh
  • , Yonggoo Kim
  • , Yeon Joon Park
  • , Kyungja Han*
  • *Corresponding author for this work
  • The Catholic University of Korea

Research output: Contribution to journalJournal articlepeer-review

Abstract

Background: The reticulocyte count is a good marker of erythropoietic activity of the bone marrow. In the mid-1990s, automated flow cytometric analysis replaced microscopy for the quantification of reticulocytes. Leukocytosis cases with an erroneously high reticulocyte count and a high immature reticulocyte fraction (IRF) have been reported. In this study, we analyzed reticulocyte counts in leukocytosis samples, in an effort to identify a correction method. Methods: The study comprised of 21 samples from 16 leukocytosis patients. Results of reticulocyte analyses obtained using a XE-2100 hematology analyzer (Sysmex, Japan) were compared with those obtained using the supravital staining technique, which is a reference method. If the samples showed erroneously high reticulocyte counts and IRF, they were reanalyzed after serial dilution with isotonic solution. Results: Five samples from 4 patients showed erroneously elevated reticulocyte counts and/or IRF on the XE-2100 analyzer. They displayed abnormal reticulocyte scattergrams, with 4 of 5 cases indicated by a flag. The white blood cell (WBC) fractions overlapped with the reticulocyte regions, especially with the IRF. Diagnoses and blast counts were variable when such errors occurred; WBC counts varied from 218.19×10 9/L to 725.14×109/L. The errors were corrected by simple dilution with isotonic solution. However, the corrective WBC counts differed according to individual cases. Conclusions: When leukocytosis samples exhibit an abnormal reticulocyte scattergram with a flag, or an abnormally high IRF, we recommend the dilution of the sample with isotonic solution to a WBC count of about 100.00×109/L, followed by reanalysis of the reticulocyte count and reticulocyte scattergram.

Original languageEnglish
Pages (from-to)392-398
Number of pages7
JournalAnnals of Laboratory Medicine
Volume32
Issue number6
DOIs
StatePublished - 2012.11

Keywords

  • Leukocytosis
  • Reticulocyte count
  • Reticulocytes

Fingerprint

Dive into the research topics of 'Correction of pseudoreticulocytosis in leukocytosis samples using the sysmex XE-2100 analyzer depends on the type and number of white blood cells'. Together they form a unique fingerprint.

Cite this