Skip to main navigation Skip to search Skip to main content

Correction: Rapid Detection of COVID-19 Causative Virus (SARS-CoV-2) in Human Nasopharyngeal Swab Specimens Using Field-Effect Transistor-Based Biosensor (ACS Nano (2020) 14:4 (5135-5142) DOI: 10.1021/acsnano.0c02823)

  • Giwan Seo
  • , Geonhee Lee
  • , Mi Jeong Kim
  • , Seung Hwa Baek
  • , Minsuk Choi
  • , Keun Bon Ku
  • , Chang Seop Lee
  • , Sangmi Jun
  • , Daeui Park
  • , Hong Gi Kim
  • , Seong Jun Kim
  • , Jeong O. Lee
  • , Bum Tae Kim
  • , Edmond Changkyun Park
  • , Seung Il Kim

Research output: Contribution to journalComment/debate

Abstract

Here, we report three errors in the published article and provide corrected results. These corrections do not affect any conclusions of the work. CorrectiontoFigure2D,E.PanelsDandEofFigure2were reversed. We correct the error by switching the panels. Correction to Figure 6. We recently realized that the clinical samples we used in Figure 6B,C of the published article were not same condition as described in the text. We used clinicalsamplesstoredineNATinsteadofinuniversaltransport medium (UTM). Universal transport medium is for collection, transport, maintenance,and long-termfreezestorageofclinicalspecimens containing viruses and is suitable for cell culture, rapid antigen detection,PCR,andnucleicacidamplificationassays.eNATisa versatile molecular medium that is designed to stabilize and to preserve microbial nucleic acids and is optimized for molecular assays.eNAT contains guanidine−thiocyanate, which isused as a general protein denaturant, and this may interfere with antigen−antibody interactions. Afterwenoticedthissampleissue,weconductedexperiments toreplaceFigure6B,C.Wesuccessfullyconfirmedthatour fieldeffect transistor (FET) sensor clearly discriminated between patientandnormalsampleswithstatisticalsignificancein0.01× UTMcondition(see correctedFigure 6B,C),which isthe same condition for detecting antigen proteins in Figure 4E. We also performed repeated experiments for determining the limit of detectionofourFETsensor.Theresultswerequitethesameas our previous data, and we compensated for the defect of statistical significance (see corrected Figure 6D,E). In addition, we evaluated the previous results using eNAT clinicalsamples.WhenweappliedtheeNATsamplestotheFET sensor for a short time, the FET sensor could discriminate patientsamples(seeoriginalFigure6B,C).Whenweappliedthe eNATsampleforalongertime,however,theFETsensordidnot detect the patient samples, perhaps as a result of protein denaturation reagents in eNAT. Therefore, clinical samples in eNAT may not be suitable for viral antigen detection assay, although the antigen−antibody interactions may be maintained for a short time. Correction of typos. On page 5140, line 10, the text reads: However, the pristine graphene-based device without SARSCoV-2 spike protein conjugation did not show any remarkable signal change after the introduction of various sample concentration (gray line in Figure 4D). The control experiment indicates that the SARS-CoV-2 spike protein is essential for... The text should be changed to: However, the pristine graphene-based device without SARSCoV-2spikeantibodyconjugationdidnotshowanyremarkable signal change after the introduction of various sample concentration (gray line in Figure 4B). The control experiment indicates that the SARS-CoV-2 spike antibody is essential for...

Original languageEnglish
Pages (from-to)12257-12258
Number of pages2
JournalACS Nano
Volume14
Issue number9
DOIs
StatePublished - 2020.09.22

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Fingerprint

Dive into the research topics of 'Correction: Rapid Detection of COVID-19 Causative Virus (SARS-CoV-2) in Human Nasopharyngeal Swab Specimens Using Field-Effect Transistor-Based Biosensor (ACS Nano (2020) 14:4 (5135-5142) DOI: 10.1021/acsnano.0c02823)'. Together they form a unique fingerprint.

Cite this