Skip to main navigation Skip to search Skip to main content

Detection of small hypervascular hepatocellular carcinomas in cirrhotic patients: Comparison of superparamagnetic iron oxide-enhanced MR imaging with dual-phase spiral CT

Research output: Contribution to journalJournal articlepeer-review

Abstract

Objective: To compare the performance of superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging at 1.5T and dual-phase spiral computed tomography (CT) for the depiction of small hypervascular hepatocellular carcinomas (HCCs). Materials and Methods: Forty-three patients with 70 small nodular HCCs (5-20 mm; mean, 13.7 mm) were examined. Diagnosis was based on the results of surgical biopsy in 22 patients and by the combined assessment of MR imaging, lipiodol CT, alpha feto-protein levels, and angiographic findings in 21. MR imaging consisted of respiratory-triggered turbo spin-echo T2-weighted imaging, T1-weighted fast low-angle shot, and T2*-weighted fast imaging with steady-state precession imaging before and after SPIO enhancement. CT imaging was performed with 5-mm collimation and 1:1.4 pitch, and began 30 and 65 secs after the injection of 150 mL of contrast medium at a rate of 3 mL/sec. Two blinded observers reviewed all images independently on a segment-by-segment basis. Diagnostic accuracy was evaluated using receiver operating characteristics (ROC) analysis. Results: The mean areas (Az) under the ROC curves were 0.85 for SPIO-enhanced MR imaging and 0.79 for dual-phase spiral CT (p < .05). The mean sensitivity of SPIO-enhanced MR imaging was significantly higher than that of CT (p < .05), i.e. 70.6% for MR imaging and 58.1% for CT. MR imaging had higher false-positive rates than dual-phase spiral CT, but the difference was not statistically significant (3.7% vs 3.3%) (p > .05). Conclusion: SPIO-enhanced MR imaging is more sensitive than dual-phase spiral CT for the depiction of small hypervascular hepatocellular carcinomas.

Original languageEnglish
Pages (from-to)1-8
Number of pages8
JournalKorean Journal of Radiology
Volume4
Issue number1
DOIs
StatePublished - 2003

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Contrast agents
  • CT liver
  • Liver
  • MR imaging liver
  • Neoplasms magnetic resonance (MR)

Quacquarelli Symonds(QS) Subject Topics

  • Medicine

Fingerprint

Dive into the research topics of 'Detection of small hypervascular hepatocellular carcinomas in cirrhotic patients: Comparison of superparamagnetic iron oxide-enhanced MR imaging with dual-phase spiral CT'. Together they form a unique fingerprint.

Cite this