Abstract
This study investigates the fire resistance characteristics of reactive powder concrete according to changes in the cement content per unit area, mixing ratio of metakaolin (MK), and content of polypropylene fiber. A fire test was conducted, and the resulting residual strength characteristics were investigated through flexural and compressive strength measurements, as well as condition rating classification based on visual evaluation. MK effectively reduced the initial high content of calcium hydroxide, thereby reducing the water vapor pressure generated during pyrolysis and slowing spalling. Furthermore, the pore structure and loose tissue were effective for relieving the water vapor pressure in the event of a fire.
| Original language | English |
|---|---|
| Pages (from-to) | 657-669 |
| Number of pages | 13 |
| Journal | Steel and Composite Structures |
| Volume | 36 |
| Issue number | 6 |
| DOIs | |
| State | Published - 2020.09.25 |
Keywords
- Fire resistance
- Metakaolin
- Pozzolanic activity
- reactive powder concrete
- Spalling properties
Quacquarelli Symonds(QS) Subject Topics
- Materials Science
- Engineering - Civil & Structural
- Architecture
Fingerprint
Dive into the research topics of 'Fire resistance and residual strength of reactive powder concrete Using metakaolin'. Together they form a unique fingerprint.Cite this