Abstract
This paper proposes a method to determine AC copper losses in permanent-magnet linear synchronous motors (PMLSMs). For PMLSMs with finite-length cores and semi-closed slots, magnetic characteristics, particularly end effects, must be considered because structural differences in the end teeth cause flux-path saturation and variations in leakage flux, which strongly influence the proximity effect. Moreover, pulse-width-modulated (PWM) currents introduce high-frequency harmonics that significantly increase the AC copper loss. To enable accurate and efficient prediction of these losses, a hybrid approach that combines analytical equations formulated for round-wire windings with finite element analysis (FEA) is proposed. The effectiveness of this proposed method is demonstrated by comparison with transient FEA, showing high accuracy while substantially reducing computation time.
| Original language | English |
|---|---|
| Pages (from-to) | 3515-3523 |
| Number of pages | 9 |
| Journal | Journal of Electrical Engineering and Technology |
| Volume | 21 |
| Issue number | 4 |
| DOIs | |
| State | Published - 2026.07 |
| Externally published | Yes |
Keywords
- AC copper loss
- Eddy current
- Frozen permeability
- Linear machine
- Magnetic equivalent circuit
Fingerprint
Dive into the research topics of 'Hybrid Method for Calculating AC Copper Loss in Permanent Magnet Linear Synchronous Motors'. Together they form a unique fingerprint.Cite this