Improvement of osseointegration of Ti–6Al–4V ELI alloy orthodontic mini-screws through anodization, cyclic pre-calcification, and heat treatments

  • Changkyun Im
  • , Je Hyeok Park
  • , Young Mi Jeon
  • , Jong Ghee Kim
  • , Yong Seok Jang
  • , Min Ho Lee
  • , Woo Yong Jeon
  • , Jun Min Kim*
  • , Tae Sung Bae*
  • *Corresponding author for this work

Research output: Contribution to journalJournal articlepeer-review

Abstract

Background: Mini-screws are widely used as temporary anchorages in orthodontic treatment, but have the disadvantage of showing a high failure rate of about 10%. Therefore, orthodontic mini-screws should have high biocompatibility and retention. Previous studies have demonstrated that the retention of mini-screws can be improved by imparting bioactivity to the surface. The method for imparting bioactivity proposed in this paper is to sequentially perform anodization, periodic pre-calcification, and heat treatments with a Ti–6Al–4V ELI alloy mini-screw. Materials and methods: A TiO2 nanotube-structured layer was formed on the surface of the Ti–6Al–4V ELI alloy mini-screw through anodization in which a voltage of 20 V was applied to a glycerol solution containing 20 wt% H2O and 1.4 wt% NH4F for 60 min. Fine granular calcium phosphate precipitates of HA and octacalcium phosphate were generated as clusters on the surface through the cyclic pre-calcification and heat treatments. The cyclic pre-calcification treatment is a process of immersion in a 0.05 M NaH2PO4 solution and a saturated Ca(OH)2 solution at 90 °C for 1 min each. Results: It was confirmed that the densely structured protrusions were precipitated, and Ca and P concentrations, which bind and concentrate endogenous bone morphogenetic proteins, increased on the surface after simulated body fluid (SBF) immersion test. In addition, the removal torque of the mini-screw fixed into rabbit tibias for 4 weeks was measured to be 8.70 ± 2.60 N cm. Conclusions: A noteworthy point in this paper is that the Ca and P concentrations, which provide a scaffold suitable for endogenous bone formation, further increased over time after SBF immersion of the APH group specimens. The other point is that our mini-screws have a significantly higher removal torque compared to untreated mini-screws. These results represent that the mini-screw proposed in this paper can be used as a mini-screw for orthodontics.

Original languageEnglish
Article number11
JournalProgress in Orthodontics
Volume23
Issue number1
DOIs
StatePublished - 2022.12

Keywords

  • Anodization
  • Cyclic pre-calcification
  • Orthodontic mini-screw
  • Osseointegration
  • Ti–6Al–4V ELI alloy

Quacquarelli Symonds(QS) Subject Topics

  • Dentistry

Fingerprint

Dive into the research topics of 'Improvement of osseointegration of Ti–6Al–4V ELI alloy orthodontic mini-screws through anodization, cyclic pre-calcification, and heat treatments'. Together they form a unique fingerprint.

Cite this