Skip to main navigation Skip to search Skip to main content

Measurement of Nasalance Scores Without Touching the Philtrum for Better Comfort During Speech Assessment and Therapy: A Preliminary Study

  • Xiaopeng Yang
  • , Gradiyan Budi Pratama
  • , Younggeun Choi
  • , Heecheon You*
  • , Nguyễn Phu ò.c.Minh Tâm
  • , Gi Wook Kim
  • , Yun Ju Jo
  • , Myoung Hwan Ko*
  • *Corresponding author for this work
  • Jiangnan University
  • Bandung Institute of Technology
  • Pohang University of Science and Technology
  • Jeonbuk National University

Research output: Contribution to journalJournal articlepeer-review

Abstract

Objective: The Kay Pentax nasometer uses a separator plate that touches the philtrum of a patient to separate the nasal and oral sound energies for nasalance measurement. However, the separator plate can restrict the natural movement of the patient’s upper lip and generate unpleasant pressure on the patient’s philtrum. The present study was intended to measure nasalance scores without touching the philtrum for better comfort during speech assessment and therapy. Methods: Nasalance scores of 10 males and 10 females having no speech disorders were measured under 4 levels (0, 5, 10, and 15 mm) of the gap between the plate and the philtrum (denoted as plate-to-philtrum gap) using Nasometer II 6450 for nasal (Nasal Sentences) and oral (Zoo Passage) stimuli. Regression formulas were established to examine the relationships between nasalance score and plate-to-philtrum gap for the stimuli. To provide nasalance scores equivalent to those measured for the contact condition, compensation factors for the 5 mm plate-to-philtrum gap measurement condition were identified for the stimuli. Results: The nasalance scores were significantly different between the 4 different plate-to-philtrum gaps for the stimuli. Compensation factors for the Nasal Sentences and the Zoo Passage were identified as 1.17 and 0.71, respectively. Conclusions: The 5 mm plate-to-philtrum gap condition after multiplying the compensation factors can provide equivalent nasalance scores to the conventional contact measurement condition which may provide better comfort in speech assessment and therapy.

Original languageEnglish
Pages (from-to)446-454
Number of pages9
JournalCleft Palate-Craniofacial Journal
Volume58
Issue number4
DOIs
StatePublished - 2021.04

Keywords

  • comfort
  • compensation factors
  • nasalance scores
  • speech therapy
  • touchless measurement

Quacquarelli Symonds(QS) Subject Topics

  • Dentistry
  • Medicine

Fingerprint

Dive into the research topics of 'Measurement of Nasalance Scores Without Touching the Philtrum for Better Comfort During Speech Assessment and Therapy: A Preliminary Study'. Together they form a unique fingerprint.

Cite this