Skip to main navigation Skip to search Skip to main content

Optimizing solvent extraction methods for activated carbon-based passive samplers in atmospheric volatile organic compound analysis: minimizing analytical interferences from pretreatment solvents and ensuring quantitative reliability

  • Jeonbuk National University

Research output: Contribution to journalJournal articlepeer-review

Abstract

A passive sampler was used to effectively monitor trace volatile organic compound (VOC) concentrations in the atmosphere. VOCs are typically extracted from passive samplers using CS2, which is a volatile and hazardous chemical that can leave residues and damage the mass spectrometry (MS) system during gas chromatography (GC)-MS. This study aims to develop and validate alternative solvent extraction methods using acetone, ethanol, n-hexane, and a solution of 99% acetone and 1% CS2 (ATCS) for VOCs from passive samplers using a standard GC-MS system. ATCS had the highest VOC extraction efficiency with the average value of 42.4 ± 21.4%, followed by acetone at 29.9 ± 17.6%. Ethanol and n-hexane exhibited extraction efficiencies of less than 9%. Despite the ATCS extraction efficiency of less than 50%, it demonstrated excellent analytical reproducibility (relative standard deviation of 1.62 ± 0.64%) and detection limit of 20.5 ± 12.9 ppt, which was significantly lower than 1 ppb. When used to extract and analyze VOCs from ambient air samples, ATCS yielded VOC concentrations of 0.57 ± 0.33 ppb, consistent with urban air levels. The variance in the outdoor VOC concentrations was less than 0.1 ppb, confirming its high reproducibility. Thus, the ATCS solvent extraction method developed in this study enables the accurate quantification of trace VOCs below 1 ppb, reduces MS damage, and mitigates health risks to analysts using GC-MS.

Original languageEnglish
Article number108187
Pages (from-to)2267-2279
Number of pages13
JournalAnalytical and Bioanalytical Chemistry
Volume417
Issue number11
DOIs
StatePublished - 2025.05

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being
  2. SDG 11 - Sustainable Cities and Communities
    SDG 11 Sustainable Cities and Communities

Keywords

  • Activated carbon-based passive sampler
  • Gas chromatography-mass spectrometry
  • Passive sampling
  • Solvent extraction
  • Volatile organic compounds

Quacquarelli Symonds(QS) Subject Topics

  • Chemistry
  • Biological Sciences

Fingerprint

Dive into the research topics of 'Optimizing solvent extraction methods for activated carbon-based passive samplers in atmospheric volatile organic compound analysis: minimizing analytical interferences from pretreatment solvents and ensuring quantitative reliability'. Together they form a unique fingerprint.

Cite this