Skip to main navigation Skip to search Skip to main content

Preliminary analyses on decontamination factors during pool scrubbing with bubble size distributions obtained from EPRI experiments

  • Yoonhee Lee*
  • , Yong Jin Cho
  • , Inchul Ryu
  • *Corresponding author for this work
  • Korea Institute of Nuclear Safety

Research output: Contribution to journalJournal articlepeer-review

Abstract

In this paper, from a review of the size distribution of the bubbles during pool scrubbing obtained from experiments by EPRI, we apply the bubble size distributions to analyses on the decontamination factors of pool scrubbing via I-COSTA (In-Containment Source Term Analysis). We perform sensitivity studies of the bubble size on the various mechanisms of deposition of aerosol particles in pool scrubbing. We also perform sensitivity studies on the size distributions of the bubbles depending on the diameters at the nozzle exit, the molecular weights of non-condensable gases in the carrier gases, and the steam fractions of the carrier gases. We then perform analyses of LACE-ESPAÑA experiments and compare the numerical results to those from SPARC-90 and experimental results in order to show the effect of the bubble size distributions.

Original languageEnglish
Pages (from-to)509-521
Number of pages13
JournalNuclear Engineering and Technology
Volume53
Issue number2
DOIs
StatePublished - 2021.02

Keywords

  • Decontamination factor
  • I-COSTA
  • LACE-ESPAÑA
  • Pool scrubbing
  • SPARC-90
  • Severe accident
  • Size distribution of bubbles

Fingerprint

Dive into the research topics of 'Preliminary analyses on decontamination factors during pool scrubbing with bubble size distributions obtained from EPRI experiments'. Together they form a unique fingerprint.