Premature failure analysis of servovalve components for a thermal power plant

  • Sung Yong Chang
  • , Joong Chel Chang
  • , Bum Soo Kim
  • , Min Woo Seo
  • , Chel Jong Choi*
  • *Corresponding author for this work
  • Korea Electric Power
  • Jeonbuk National University

Research output: Contribution to journalJournal articlepeer-review

Abstract

The premature failure of a servovalve used for six months in a thermal power plant has been analyzed. The servovalve was made of stainless steel, containing 16Cr-0.44Mo, along with other elements. An overload of oil-supply pumping and an abnormal increase in the oil flux were observed during operation. A study revealed that erosion and corrosion could be the main causes of the failure. The visual examination of the servovalve did not show any appreciable damage. However, corrosion and erosion of the servovalve were observed using scanning electron microscopy (SEM). Upon examination of the servovalve, the corrosion was found to have occurred throughout the bushing and spool; however, erosion occurred at only the edge-side. In addition, the condition of the electrohydraulic control system (EHC) oil was investigated with respect to its satisfaction of the management standard.

Original languageEnglish
Pages (from-to)708-714
Number of pages7
JournalJournal of Korean Institute of Metals and Materials
Volume49
Issue number9
DOIs
StatePublished - 2011.09

Keywords

  • Alloys
  • Corrosion
  • Deformation
  • Scanning electron microscopy (sem)
  • Servovalve