Skip to main navigation Skip to search Skip to main content

Pumpless three-dimensional photo paper–based microfluidic analytical device for automatic detection of thioredoxin-1 using enzyme-linked immunosorbent assay

  • Myeong Jun Lee
  • , Veasna Soum
  • , Sang Nam Lee
  • , Jin Ha Choi
  • , Jeong Hyeop Shin
  • , Kwanwoo Shin*
  • , Byung Keun Oh*
  • *Corresponding author for this work
  • Sogang University
  • Royal University of Phnom Penh

Research output: Contribution to journalJournal articlepeer-review

Abstract

Microfluidic-based biosensors have been developed for their precise automatic reaction control. However, these biosensors require external devices that are difficult to transport and use. To overcome this disadvantage, our group made an easy-to-use, cheap, and light pumpless three-dimensional photo paper–based microfluidic analytical device (3D-μPAD; weight: 1.5 g). Unlike conventional paper-based microfluidic analytical devices, the 3D-μPAD can be used to control fluid flow in a 3D manner, thus allowing sophisticated multi-step reaction control. This device can control fluid flow speed and direction accurately using only the capillary-driven flow without an external device like a pump. The flow speed is controlled by the width of the microfluidic channel and its surface property. In addition, fluid speed control and 3D-bridge structure enable the control of fluid flow direction. Using these methods, multi-step enzyme-linked immunosorbent assay (ELISA) can be done automatically in sequence by injecting solutions (sample, washing, and enzyme’s substrate) at the same time in the 3D-μPAD. All the steps can be performed in 14 min, and data can be analyzed immediately. To test this device, thioredoxin-1 (Trx-1), a biomarker of breast cancer, is used as the target. In the 3D-μPAD, it can detect 0–200 ng/mL of Trx-1, and the prepared 3D-μPAD Trx-1 sensor displays excellent selectivity. Moreover, by analyzing the concentration of Trx-1 in real patients and healthy individuals’ blood serum samples using the 3D-μPAD, and comparing results to ELISA, it can be confirmed that the 3D-μPAD is a good tool for cancer diagnosis. Graphical abstract: [Figure not available: see fulltext.]

Original languageEnglish
Pages (from-to)3219-3230
Number of pages12
JournalAnalytical and Bioanalytical Chemistry
Volume414
Issue number10
DOIs
StatePublished - 2022.04

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Colorimetric
  • ELISA
  • Microfluidics
  • Photo paper
  • Point-of-care
  • Thioredoxin-1

Quacquarelli Symonds(QS) Subject Topics

  • Chemistry
  • Biological Sciences

Fingerprint

Dive into the research topics of 'Pumpless three-dimensional photo paper–based microfluidic analytical device for automatic detection of thioredoxin-1 using enzyme-linked immunosorbent assay'. Together they form a unique fingerprint.

Cite this