Abstract

HfS2 is a layered semiconductor for electronic and optoelectronic applications, but humidity-assisted native oxidation limits its ambient stability. Raman spectroscopy probes HfS2 degradation but is time-consuming and condition-sensitive. Here, we revisit a previously reported HfS2 aging dataset to develop a Raman-calibrated image-based framework for rapid, non-destructive screening of CVD-grown HfS2 films on c-plane sapphire. Photographs collected under a documented configuration yielded predefined color, histogram, texture, and spatial descriptors. A simple, interpretable regression using only CIE Lab b* with physical-range clipping achieved a within-library, query-excluded leave-one-day-out RMSE of 6.78 days for 21 queries from three optically evolving conditions: native HfS2 at 35% and 70% RH and PMMA-capped HfS2 at 70% RH. The b*-based model performed comparably to kNN (7.70 days) and significantly better than a no-information pool-mean baseline (9.84 days, p = 0.0030), indicating that more complex estimators provided no clear benefit in the present dataset. Under leave-one-pair-out evaluation of 20 image-Raman pairs, the combined image-derived estimate showed a trend-level relationship with measured normalized A1g intensity (R2 = 0.600), while ΔE gave the best individual result (R2 = 0.701). The framework identified its limits: severe degradation of native HfS2 at 70% RH was underestimated, whereas Al2O3-encapsulated HfS2 showed insufficient optical evolution for reliable chronological estimation. Accordingly, this material- and configuration-specific method is a proof-of-concept screening framework, not a universal dating model or a substitute for Raman spectroscopy. Within this scope, controlled photography provides interpretable pre-screening of broad aging states and prioritizes samples for Raman or chemical analysis.

Original languageEnglish
Article number111122
JournalMaterials Science in Semiconductor Processing
Volume217
DOIs
StatePublished - 2027.01

Keywords

  • HfS
  • Image-based screening
  • Native oxidation
  • Raman-calibrated imaging
  • Thin-film aging

Fingerprint

Dive into the research topics of 'Raman-calibrated image-based screening of ambient aging in CVD-grown HfS2 thin films'. Together they form a unique fingerprint.

Cite this