Skip to main navigation Skip to search Skip to main content

Removal of As(V) from aqueous system using steel-making by-product

  • Chil Sung Jeon
  • , Tserennyam Batjargal
  • , Chang Il Seo
  • , Jung Seok Yang
  • , Kitae Baek*
  • *Corresponding author for this work
  • Kumoh National Institute of Technology
  • Environmental Management Corporation
  • Korea Institute of Science and Technology

Research output: Contribution to journalJournal articlepeer-review

Abstract

For As(V) removal aqueous system, 3 types slag which is a waste product from steel making process was used. Arsenic was mainly removed by Ca-As precipitation such as form Ca3(AsO4)2. The removal efficiency of arsenic on slag was affected by iron oxide contents because arsenic was removed by adsorption on iron oxide. The experimental results were well fitted by pseudo-second-order and Langmuir isotherm model compared to other models. Arsenic was completely removed by Slag Y and Slag J within 12 h, 0.5 g and 0.7 g of Slag Y and Slag J are sufficient to remove arsenic of 20 mg/l arsenic. The removal efficiency increases with the decrease of initial pH and the decrease of initial arsenic concentration. The calcium that is a major component comes from dissolution of the lime (CaO). The calcium concentration increased at low initial pH because the solubility of the lime (CaO) increases at acidic condition. The equilibrium pH sharply increase after reaction because of creation of hydroxide ion.

Original languageEnglish
Pages (from-to)152-159
Number of pages8
JournalDesalination and Water Treatment
Volume7
Issue number1-3
DOIs
StatePublished - 2009.07

Keywords

  • Arsenic
  • Langmuir
  • Precipitation
  • Pseudo-second-order
  • Steel making slag

Fingerprint

Dive into the research topics of 'Removal of As(V) from aqueous system using steel-making by-product'. Together they form a unique fingerprint.