TY - GEN
T1 - STUDY ON THE EFFECT OF VOLUMETRIC CHANGE, ICE STRUCTURE AND HEATING CONDITION ON ICE MELTING SIMULATION
AU - Kang, Chaedong
AU - Okawa, Seiji
AU - Saito, Akio
N1 - Publisher Copyright:
© 1998, Begell House Inc. All rights reserved.
PY - 1998
Y1 - 1998
N2 - It is important to know the behavior of hydrogen bonding in order to understand the mechanism of melting of ice in micro scale. The object of this study is to investigate the various conditions affecting the simulation on ice melting such as boundary condition, method of volumetric change, crystal structure and heating condition. TIP4P (Tour-sited Transferable Intennolecular Potential, W.L. Jorgensen, J. Chandrasekhr, J.D. Madura, R.W. Impey, and M.L. Klein, 1983) model was selected as water model. First of all, volumetric change condition was considered and melting point of anisotropic condition was found to be closer to macroscopic value than isotropic one which produce an unbalanced stress on ice. Secondly, the effect on the difference of ice structure was considered using two extreme arrangements, i.e., ferromagnetic and anti-ferromagnetic structure. According to the stability of potential distribution, melting point and latent heat of the latter was closer to the nature than the former. Thirdly, the effect of the heating condition was observed and found that the melting point was closer to macroscopic value in a case of heating from a wall comparing to that of heating all molecules or point heating.
AB - It is important to know the behavior of hydrogen bonding in order to understand the mechanism of melting of ice in micro scale. The object of this study is to investigate the various conditions affecting the simulation on ice melting such as boundary condition, method of volumetric change, crystal structure and heating condition. TIP4P (Tour-sited Transferable Intennolecular Potential, W.L. Jorgensen, J. Chandrasekhr, J.D. Madura, R.W. Impey, and M.L. Klein, 1983) model was selected as water model. First of all, volumetric change condition was considered and melting point of anisotropic condition was found to be closer to macroscopic value than isotropic one which produce an unbalanced stress on ice. Secondly, the effect on the difference of ice structure was considered using two extreme arrangements, i.e., ferromagnetic and anti-ferromagnetic structure. According to the stability of potential distribution, melting point and latent heat of the latter was closer to the nature than the former. Thirdly, the effect of the heating condition was observed and found that the melting point was closer to macroscopic value in a case of heating from a wall comparing to that of heating all molecules or point heating.
UR - https://www.scopus.com/pages/publications/105042633350
U2 - 10.1615/IHTC11.990
DO - 10.1615/IHTC11.990
M3 - Conference paper
AN - SCOPUS:105042633350
SN - 9781560327974
T3 - International Heat Transfer Conference
SP - 145
EP - 150
BT - International Heat Transfer Conference 11
PB - Begell House Inc.
T2 - 11th International Heat Transfer Conference, 1998
Y2 - 23 August 1998 through 28 August 1998
ER -