Skip to main navigation Skip to search Skip to main content

The effects of a magnetic field dependent critical current on the hysteresis loss of a coated conductor

  • Jaeun Yoo*
  • , Sangmoo Lee
  • , Yehyun Jung
  • , Jaeyoung Lee
  • , Dzung Nguyen Xuan
  • , Dojun Youm
  • , Hosup Kim
  • , Hongsoo Ha
  • , Kyujeong Song
  • , Sangsoo Oh
  • , Sangjun Oh
  • *Corresponding author for this work
  • Korea Advanced Institute of Science and Technology
  • Korea Electrotechnology Research Institute
  • National Fusion Research Center

Research output: Contribution to journalJournal articlepeer-review

Abstract

We calculated the current distribution in a coated conductor (CC) from magnetic induction profiles measured using the scanning Hall probe method. An external magnetic field was applied in the normal direction with respect to the tape surface and was decreased stepwise from Hpeak to -H peak. From the hysteretic behavior of the current distributions, the energy loss, QM, was calculated for various values of H peak. Comparison of the present results with Brandt's theoretical calculations revealed that his formula is still valid if one substitutes the magnetic field dependent critical current density into his equation. The theoretical results obtained were consistent with the experimental QM values obtained.

Original languageEnglish
Article number085020
JournalSuperconductor Science and Technology
Volume21
Issue number8
DOIs
StatePublished - 2008.08.1

Fingerprint

Dive into the research topics of 'The effects of a magnetic field dependent critical current on the hysteresis loss of a coated conductor'. Together they form a unique fingerprint.

Cite this