Skip to main navigation Skip to search Skip to main content

The effects of exhaust gas recirculation on premixed type condensing boiler

  • Jinsu Kim
  • , Byeonghun Yu
  • , Seungro Lee
  • , Sung Min Kum
  • , Chang Eon Lee*
  • *Corresponding author for this work
  • Inha University
  • Cheju Halla University

Research output: Conference(x)Paperpeer-review

Abstract

The premixed combustion system as the preheated air condensing boiler applying exhaust gas recirculation (EGR) was investigated to achieve the low pollutant emission and the high thermal efficiency. In this study, it was studied the effects of EGR on the thermal efficiency, NOx and CO emissions with various EGR and equivalence ratios, numerically and experimentally. As results, when the equivalence ratio increased, thermal efficiency and NOx and CO concentrations increased. Especially, in the case of 15% of EGR ratio at 0.85 of equivalence ratio, NOx and CO concentrations were a smaller than these of the current operating condition of the boiler (φ=0.78) and the thermal efficiency was approximately 1.7% higher.

Original languageEnglish
StatePublished - 2013
Event9th Asia-Pacific Conference on Combustion, ASPACC 2013 - Gyeongju, Korea, Republic of
Duration: 2013.05.192013.05.22

Conference

Conference9th Asia-Pacific Conference on Combustion, ASPACC 2013
Country/TerritoryKorea, Republic of
CityGyeongju
Period13.05.1913.05.22

Fingerprint

Dive into the research topics of 'The effects of exhaust gas recirculation on premixed type condensing boiler'. Together they form a unique fingerprint.

Cite this