The potential role of grid-like software in bedside chest radiography in improving image quality and dose reduction: An observer preference study

  • Su Yeon Ahn
  • , Kum Ju Chae
  • , Jin Mo Goo*
  • *Corresponding author for this work

Research output: Contribution to journalJournal articlepeer-review

Abstract

Objective: To compare the observer preference of image quality and radiation dose between non-grid, grid-like, and grid images. Materials and Methods: Each of the 38 patients underwent bedside chest radiography with and without a grid. A grid-like image was generated from a non-grid image using SimGrid software (Samsung Electronics Co. Ltd.) employing deep-learningbased scatter correction technology. Two readers recorded the preference for 10 anatomic landmarks and the overall appearance on a five-point scale for a pair of non-grid and grid-like images, and a pair of grid-like and grid images, respectively, which were randomly presented. The dose area product (DAP) was also recorded. Wilcoxon’s rank sum test was used to assess the significance of preference. Results: Both readers preferred grid-like images to non-grid images significantly (p < 0.001); with a significant difference in terms of the preference for grid images to grid-like images (p = 0.317, 0.034, respectively). In terms of anatomic landmarks, both readers preferred grid-like images to non-grid images (p < 0.05). No significant differences existed between grid-like and grid images except for the preference for grid images in proximal airways by two readers, and in retrocardiac lung and thoracic spine by one reader. The median DAP were 1.48 (range, 1.37−2.17) dGy*cm2 in grid images and 1.22 (range, 1.11−1.78) dGy*cm2 in grid-like images with a significant difference (p < 0.001). Conclusion: The SimGrid software significantly improved the image quality of non-grid images to a level comparable to that of grid images with a relatively lower level of radiation exposure.

Original languageEnglish
Pages (from-to)526-533
Number of pages8
JournalKorean Journal of Radiology
Volume19
Issue number3
DOIs
StatePublished - 2018.05.1

Keywords

  • Bedside chest radiography
  • Dose reduction
  • Grid
  • Image quality
  • Scatter correction
  • Software

Quacquarelli Symonds(QS) Subject Topics

  • Medicine

Fingerprint

Dive into the research topics of 'The potential role of grid-like software in bedside chest radiography in improving image quality and dose reduction: An observer preference study'. Together they form a unique fingerprint.

Cite this