Abstract
Tuned Liquid damper and Tuned Liquid Column are kind of passive mechanical damper which relies on the sloshing of liquid in a rigid tank for suppressing structural vibrations. TLD and TLCD are attributable to several potential advantages - low costs; easy to install in existing structures; effective even for small-amplitude vibrations. In this paper, the shaking table experiments were conducted to investigate the characteristics of water sloshing motion in TLD (rectangular, circular) and TLCD. The parameter obtained from the experiments were wave height, base shear force and energy dissipation. The shaking table experiments show that the liquid sloshing relies on amplitude of shaking table and frequency of tank. The TLCD was more effective control vibration than TLD.
| Original language | English |
|---|---|
| Pages (from-to) | 795-805 |
| Number of pages | 11 |
| Journal | Journal of Mechanical Science and Technology |
| Volume | 20 |
| Issue number | 6 |
| DOIs | |
| State | Published - 2006.06 |
Keywords
- Base Shear Force
- Energy Dissipation
- Shaking Table
- Tuned Liquid Column
- Tuned Liquid Damper
- Wave
Quacquarelli Symonds(QS) Subject Topics
- Materials Science
- Engineering - Mechanical
Fingerprint