The vibration performance experiment of tuned liquid damper and tuned liquid column damper

  • Young Moon Kim*
  • , Ki Pyo You
  • , Ji Eun Cho
  • , Dong Pyo Hong
  • *Corresponding author for this work

Research output: Contribution to journalJournal articlepeer-review

Abstract

Tuned Liquid damper and Tuned Liquid Column are kind of passive mechanical damper which relies on the sloshing of liquid in a rigid tank for suppressing structural vibrations. TLD and TLCD are attributable to several potential advantages - low costs; easy to install in existing structures; effective even for small-amplitude vibrations. In this paper, the shaking table experiments were conducted to investigate the characteristics of water sloshing motion in TLD (rectangular, circular) and TLCD. The parameter obtained from the experiments were wave height, base shear force and energy dissipation. The shaking table experiments show that the liquid sloshing relies on amplitude of shaking table and frequency of tank. The TLCD was more effective control vibration than TLD.

Original languageEnglish
Pages (from-to)795-805
Number of pages11
JournalJournal of Mechanical Science and Technology
Volume20
Issue number6
DOIs
StatePublished - 2006.06

Keywords

  • Base Shear Force
  • Energy Dissipation
  • Shaking Table
  • Tuned Liquid Column
  • Tuned Liquid Damper
  • Wave

Quacquarelli Symonds(QS) Subject Topics

  • Materials Science
  • Engineering - Mechanical

Fingerprint

Dive into the research topics of 'The vibration performance experiment of tuned liquid damper and tuned liquid column damper'. Together they form a unique fingerprint.

Cite this