Abstract
The conventional single-phase quasi-Z-source (QZS) inverter has a high leakage current as it is connected to the grid. To address this problem, this paper proposes a transformerless QZS inverter, which can reduce the leakage current for single-phase grid-tied applications. The proposed inverter effectively alleviates the leakage current problem by removing high-frequency components for the common-mode voltage. The operation principle of the proposed inverter is described together with its control strategy. A control scheme is presented for regulating the DC-link voltage and the grid current. A 1.0 kW prototype inverter was designed and tested to verify the performance of the proposed inverter. Silicon carbide (SiC) power devices were applied to the proposed inverter to increase the power efficiency. The experimental results showed that the proposed inverter achieved high performance for leakage current reduction and power efficiency improvement.
| Original language | English |
|---|---|
| Article number | 312 |
| Journal | Electronics (Switzerland) |
| Volume | 8 |
| Issue number | 3 |
| DOIs | |
| State | Published - 2019.03 |
Keywords
- Grid-tied
- Leakage current
- Power efficiency
- Quasi-z-source inverter
Quacquarelli Symonds(QS) Subject Topics
- Computer Science & Information Systems
- Engineering - Electrical & Electronic
- Engineering - Petroleum
- Data Science
Fingerprint
Dive into the research topics of 'Transformerless Quasi-Z-source inverter to reduce leakage current for single-phase grid-tied applications'. Together they form a unique fingerprint.Cite this