Skip to main navigation Skip to search Skip to main content

Value of adding T1-weighted image to MR cholangiopancreatography for detecting intrahepatic biliary stones.

  • Young Kon Kim*
  • , Chong Soo Kim
  • , Jeong Min Lee
  • , Seog Wan Ko
  • , Gyung Ho Chung
  • , Seung Ok Lee
  • , Young Min Han
  • , Sang Yong Lee
  • *Corresponding author for this work
  • Jeonbuk National University

Research output: Contribution to journalJournal articlepeer-review

Abstract

OBJECTIVE: The purpose of this study was to assess the value of adding a T1-weighted image to MR cholangiopancreatography (MRCP) to detect bile duct stones. MATERIALS AND METHODS: During a 30-month period, 148 patients suspected of having biliary stones and who underwent MRI including MRCP, a fat-suppressed T1-weighted fast low-angle shot (FLASH) sequence, and an axial HASTE sequence were enrolled in this study. The biliary stones were confirmed by ERCP, surgery, and percutaneous transhepatic cholangiography. Of these 148 patients, 73 had extrahepatic stones, 45 had intrahepatic stones, 20 had both extrahepatic and intrahepatic stones, and 10 had no biliary stones. Two separate sets of images, the MRCP set (composed of MRCP and axial HASTE) and the combined interpretion of the MRCP set and the T1-weighted image, were analyzed independently and separately by two observers. The diagnostic accuracy was evaluated using the receiver operating characteristic method. The sensitivity and specificity were also calculated. RESULTS: For common duct stones, the diagnostic accuracy and the sensitivity of both image sets showed similar values without any significant difference (0.998 [97.8%] for the combined interpretation; 0.988 [97.8%] for observer 1 and 0.995 [96.8%] for observer 2 for the MRCP set). However, for the intrahepatic stones, the diagnostic accuracy (0.993) and the sensitivity (98.5%) of the combined interpretation were significantly higher than those of the MRCP set for the two observers (0.926 [83.8%] for observer 1 and 0.922 [85.3%] for observer 2) (p < 0.05). No significant difference was seen in the specificity of the two image sets for both the intrahepatic and the common duct stones. CONCLUSION: Combining the axial T1-weighted image with MRCP is valuable for detecting intrahepatic stones.

Original languageEnglish
Pages (from-to)W267-274
JournalAmerican Journal of Roentgenology
Volume187
Issue number3
DOIs
StatePublished - 2006

Quacquarelli Symonds(QS) Subject Topics

  • Medicine

Fingerprint

Dive into the research topics of 'Value of adding T1-weighted image to MR cholangiopancreatography for detecting intrahepatic biliary stones.'. Together they form a unique fingerprint.

Cite this